Montreal Fire Door locks Inspection โ€“ Fire Safety & Compliance

๐Ÿ”ฅ Montreal Fire Door Inspection โ€“ Fire Safety & Compliance

Attention building owners and property managers! ๐Ÿข๐Ÿ”ฅ The fire department performs annual inspections to ensure your building is safe and compliant. At Serrurier Shay Locksmith, we specialize in inspecting, repairing, and maintaining all doors so you can pass inspections stress-free.


โœ… What We Check During Door Inspections:

Latching Issues โš ๏ธ

  • Doors must latch properly.
  • Doors that close too fast or too slow are unsafe.

Obstructions & Misalignment ๐Ÿ›‘

  • Doors that donโ€™t fully close due to closer arms or frame interference.

Fire-Rated Plates ๐Ÿ”ฅ

  • Fire-rated labels/plates must be clean, visible, and free of paint.

Push Paddles & Exit Devices ๐Ÿ–๏ธ

  • Main doors: push paddles must function properly.
  • Exit doors: push bars must fully retract (100%) when pressed.

Door Closers ๐Ÿ’ง

  • Check for oil leaks and proper operation.

Electric Strikes & Strike Plates โšก

  • Replace missing or damaged parts.

Door Hinges ๐Ÿ”ฉ

  • Replace missing or worn hinges to ensure proper door operation.

Handles & Hardware ๐Ÿ–๏ธ

  • Repair or replace missing or broken handles.

Garbage Chute Doors & Windows ๐Ÿ—‘๏ธ

  • Doors must close automatically.
  • Chute windows must close automatically after use.
  • Doors/windows left open are serious fire hazards.

Exit Door Requirements ๐Ÿšช

  • Must always be clear and unobstructed.
  • No additional locks allowed.
  • Only permitted device: removable weldable bar (common in warehouses).

โšก How to Speed Up the Inspection:

To save time and labor costs, clients should:

  • Mark all doors with yellow notes or tape ๐ŸŸจ.
  • Mark floors and door locations clearly.
  • Send a diagram if you cannot be on-site ๐Ÿ—บ๏ธ.
  • Best option: Be on-site with us to show all doors ๐Ÿง‘โ€๐Ÿ”ง.

If no markings or on-site guidance are provided, labor time may increase.


๐Ÿ› ๏ธ Step-by-Step Inspection Process:

  1. Full walkthrough of all doors ๐Ÿšถโ€โ™‚๏ธ
  2. Check latches, closers, push paddles, hinges, handles, electric strikes, and exit devices ๐Ÿ”ง
  3. Inspect garbage chute doors and windows to ensure they self-close properly ๐Ÿ—‘๏ธ
  4. Clean fire-rated plates and remove paint/obstructions ๐Ÿ–Œ๏ธ
  5. Repair or replace defective hardware โš™๏ธ
  6. Confirm all exit paths are clear and compliant โœ…

๐Ÿ“ง Email: info@serruriermontreal.com
๐Ÿ“ž Call: 514-836-9097

Make sure your building is safe, compliant, and ready for inspection! ๐Ÿ”ฅ๐Ÿšช๐Ÿ’ช